Thursday, 23 March 2017

LFG Open Flare system supplied to Ramky Enviro Engineers Ltd. for the flaring of Landfill Gas.



Combustion Research Associates successfully designed, manufactured & commissioned an LFG Open Flare System for our client Ramky Enviro Engineers Ltd. 


Biogas Flaring systems and Landfill Gas Flares are installed at Landfills, Wastewater facilities, Digesters etc. to dispose of waste gases such as Landfill gas (LFG), Biogas, Syn gas, Producer gas, Sewage gas and Agricultural or Industrial Digester gas that are formed due to the anaerobic decomposition of biomass and organic matter. 

Our design for Open Flare System was having capacity 30 N Cu. Mtr./ Hr.

This Flare System was supplied on October – 2014.
.
Specifications of the installed System are as follows:
System            :           Open Flare System
Capacity          :           30 N Cu. Mtr./ Hr.
Medium           :           Landfill Gas
Purpose          :           Flaring of Landfill Gas

Update: The system is satisfactorily in operation.

Friday, 3 March 2017

Gas Scrubber Supplied To Enviro Control Associates For The Conditioning Of Biogas



Combustion Research Associates successfully designed, manufactured & commissioned Biogas Scrubbing System for our client Enviro Control Associates. 

Manufactured under technological collaboration with M/s S & H Umweltengineering Germany, our Bio-trickling filters have been installed at more than 200 different locations for various applications such as odour control and (Hydrogen Sulfide) H2S removal at Food Processing Plants, Pulp and Paper Plants, Rendering Plants and Waste Water Treatment Plants (WWTP).

Our design for Gas Scrubbing System was having capacity 250 N Cu. Mtr./ Hr.

This Flare System was supplied on November – 2013.
.
Specifications of the installed System are as follows:
System            :           Biogas H2S Scrubbing System
Capacity          :           250 N Cu. Mtr./ Hr.
Medium           :           Biogas
Purpose          :           Conditioning of Biogas